Plastic Single Jet Dry Dial Water Meter
Model: LXSC-15-20
Classification: Single Jet Dry Type

Ningbo Ammete meter technology has specialized in the water meter industry for over 30 years, providing a one-stop service to clients. We insist on improving water meter measurement performance and keep pursuing a high-quality water meter. Contact us for more information +86-0574-87357358

Product Video
Product Details

Application:

Single-jet water meters are excellent choices for billing and water monitoring in commercial and industrial applications, as well as for batch control and domestic use.

Features:

  • Smaller in size and light weight
  • The register is isolated from water, ensure clear readings over a long period of use
  • A dry top single-jet design, which is simple, accurate, and has a wide flow range
  • Magnetic drive, lower transmission resistance, Not affected by an external magnetic field
  • The clockwork is vacuum-sealed to prevent water condensation inside and frost resistance
  • Low price, economically practical
  • Additional Inlet strainer provide better resistance to water impurities
  • Accressories: 2pcs coupling, 2pcs coupling nuts and 2pcs washers

Customized Features:

  • Body material: Brass/Nylon Plastic/Stainless Steel
  • Accuracy: R80/R100
  • Size: 15~20mm
  • Cold / Hot water
  • Pulse output option

Working Conditions:

Water temperature≤50℃ (Hot water meter≤90℃)
Water pressure≤1MPa Or 1.6MPa
△P≤63

Dimension:

* Data based on brass body

Type Nominal Size(mm) Size (inch) Length Width Height Connecting Thread D
LXSC-15 15 1/2″ 110 66 63 G¾B
LXSC-20 20 3/4″ 130 66 65 G1 B

Accuracy

From minimum flow-rate(Q1) inclusive, to transitional flow -rate(Q2) exclusive:±5%
From transitional flow- rate(Q2) inclusive, to overload flow -rate(Q4) exclusive:±2%
Hot water meter ±3%

Technical Data:

Model Number Unit LXSC-15 LXSC-20
Nominal Size mm(inch) 15(1/2″) 20(3/4″)
Overload Flow Rate (Q4) m3h 3.125 5
Permanent Flow Rate (Q3) m3h 2.5 4
R=80 Transitional Flow Rate (Q2) m3/h 0.05 0.08
Minimum Flow Rate (Q1) m3/h 0.0312 0.05
R=100 Transitional Flow Rate (Q2) m3/h 0.04 0.064
Minimum Flow Rate (Q1) m3/h 0.025 0.04
Min. Reading m3 0.0001 0.0001
Max. Reading m3 99999 99999
Temperature class T °C T50/T90
Water pressure classes MPa 1.0/1.6
Pressure-loss classes △P63
Instalation Positions HORIZONTAL

Copyright © 2023 Ningbo Ammete Meter Technology Co., Ltd. All rights reserved.Website Support: ZiYu A.D.

 